What was found
FWD CARGO WEB CRACKED AT FASTENER HOLE BS 500 - BS 500A RBL 22 WL 154 ; / [01] REMOED WEB AT FWD CARGO BS 500 - BS 500A RBL 22 WL 154 IAW SRM 51-40-02-0G-0; [02] WEB FORMING AND HEAT TREATMENT ACCOMPLISHED ON PO#839725/1.; [03] LOCATED AND DRILLED REPLACEMENT WEB; APPLIED CHEMICAL CONV. COATING PER DWG# 143A0080 REV:-; SRM 51-40-05-0G-0 AND SOPM 20-43-03. OK TO PRIME.; [04] VERIFIED CORRECTIVE ACTION 3.; [05] APPLIED PRIMER TO FWD CARGO WEB BS 500-500A RBL 22 WL 154 PER AMM 51-21-72-370-804. OK TO INSTALL WEB ASSY.; [06] VERIFIED STEP 5.; [07] INSTALLED FCB WEB BS 500-500A; RBL 22 WL 154 PER SRM 51-40-02; DWG#143A0080.; [08] VERIFIED INSTALLED FCB WEB BS 500-500A; RBL 22 WL 154 PER SRM 51-40-02; DWG#143A0080.; [09] WORKSCOPE COMPLETE