What was found
AFT UPPER FUSELAGE AT STA 1016 - STA 1088 STR 3L - STR 3R WL 308.5 HAS SURFACE CORROSION. REMOVED CORROSION ON UPPER FUSELAGE FROM BS 1016 TO 1088, BETWEEN STRINGER 3L AND 3R, WL 308.5 IAW SRM 51-10-02-0G-0. NO MATERIAL LOST AREAS WITHIN LIMITS IAW SRM 53-00-01-1A-1DETAIL C & FIG. 104. TREATED AND PRIMED AREA IAW AMM 51-21-41-370-802 & 51-21-72-370-804. INSTALLED FASTENERS AND SUPPORT BRACKET IAW SRM 51-40-02-0G-0.