What was found
CRACKED INTERCOSTAL AT B.S. 312-328; L.B.L. 47; W.L. 208.1. ; / [01] REMOVED CRACKED INTERCOSTAL AT BS 312-328 ; LBL 47 WL 208.1 DUE TO NO ALLOWABLE LIMITS FOR CRACKS FOR THIS PART IAW SRM 51-10-02; [02] LOCATED AND DRILLED NEW INTERCOSTAL AT BS 312-328 LBL 47 WL 208.1 IAW SRM 51-40-05 OK TO INSTALL; [03] VERIFIED CORRECTIVE ACTIONS 1 AND 2; [04] INSTALLED NEW INTERCOSTAL AT BS 312-328 LBL 47 WL 208.1 IAW SRM 51-40-02AND DWG #141A5400; [05] VERIFIED INSTALLED NEW INTERCOSTAL AT BS 312-328 LBL 47 WL 208.1 IAW SRM 51-40-02AND DWG #141A5400