FWD CARGO BAY; FLOOR TO SIDE WALL SUPPORT CORRODED;BS460+10; 14. LBL24; WL156 ; / [01] REMOVED CORROSION ON SIDEWALL SUPPORT AT DISCREPANCY AREA FOUND TO BE OUT OF LIMITS AT BS.460+14 . L=1.5' W=0.5' D=0.015' ORIGINAL THICKNEES 0.040' IAW SRM 53-00-53-1A-2 . FIG 103 USED TOOL ID ATS 1672 DATE DUE 03/2022; [02] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD # TTG8Q006SQQM.; [03] VERIFIED CORRECTIVE ACTION 1.; [04] VERIFIED CORRECTIVE ACTION 2; THIS FAULT WILL BE ACCOMPLISHED ON CUSTOMER CARD #TTG8Q006SQQM; [05] UPDATED MEASUREMENT TABLE.