What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS895 RBL21 WL170. ; / [01] DAMAGE FOUND ON ACB AFT SIDEWALL SUPPORT BS895 RBL21 WL 170 P/N 147A7501-17;AREA OT=0.040 RT=0.035 X=0.005 L=0.600 W=0.300; <BR>WITH MICROMETER ID IS000686 <BR>SN:67171914 <BR>DATE:03/2021 <BR>DUE:03/2022 <BR> FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 PAR 4.A(2) AND IT WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G PAR 9C.; [02] VERIFIED CORRECTIVE ACTION 1; [03] REMOVED FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS 867-947 ;RBL 21 WL 170 IAW SRM 51-40-02.; [04] FABRICATED LOCATED AND DRILLED ACB FLOOR TO SIDE WALL SUPPORT ANGLE BS 867 TO BS 947 RBL 21 SPLICED ANGLE AT BS 887 MADE FROM BAC1496-377 LOT#5095753-1 EXTRUSION IAW SRM 51-40-05-0G-0 AND DWG#147A7500 OK TO TREAT AND PRIME; [05] VERIFIED CORRECTIVE ACTION ITEM 4.; [06] OK TO APPLY CHEMICAL CONVERSION COATING & PRIMER.; [07] APPLIED CHEMICAL CONVERSION COATING AND PRIMED ACB FLOOR TO SIDE WALL SUPPORT ANGLE BS 867 TO BS 947 RBL 21 IAW SRM 51-20-01-0G-0 AND SOPM 20-41-02; [08] VERIFIED CORRECTIVE ACTION ITEM 7.; [09] OK TO INSTALL.; [10] OK TO INSTALL; [11] INSTALLED NEW SIDEWALL SUPPORT AT AFT CARGO BAY BS 867 TO BS 947 RBL 21` WL 170 ;MADE FROM BAC 1496-377 LOT# 5095753-1 EXTRUSION IAW SRM 51-40-02; DWG 147A7500 REV:- AND DWG 146A7502 REV:A.; [12] VERIFIED INSTALLATION OF ACB FLOOR-TO-SIDEWALL SUPPORT; BS 867-947; RBL 21; WL 170; PER SRM 51-40-02; DWG 147A7500 AND DWG 146A7502; [13] INSPECTION COMPLETE