What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS947 RBL12 WL177. ; / [01] REMOVED CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE P/N 149A8118-29 AT BS 947; RBL 12; WL 177; AREA 2.5' X 1' X .020' IAW SRM51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM; IT'LL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.<BR><BR>TOOL USED ID: IS000686 ; 67171914; [02] REMOVED AND REPLACED AFT BULKHEAD TO FLOOR SUPPORT ANGLE P/N 149A8118-29 AT BS 947; RBL 12; WL 177 WILL BE ACCOMPLISHED ON C.C. TTG8Q006SXB5.; [03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2; [04] ALL WORK COMPLETED; REMOVAL AND INSTALLATION OF NEW BULKHEAD TO FLOOR SUPPORT ANGLE ACCOMPLISHED ON CUSTOMER CARD TTG8Q006SXB5; [05] VERIFIED CORRECTIVE ACTION ENTRY 4.