What was found
CORROSION ON ATTACH ANGLE AT AFT CARGO BAY BS727D+5 LBL5 WL151. ; CORROSION ON ATTACH ANGLES AT AFT CARGO BAY BS 727D+5 LBL5 AND 727D+5 LBL4 WL151 / [01] EVALUATED DAMAGE IN ATTACH ANGLE ACB AT BS 727D+5 LBL5 WL151 FOUND TO BE OUT LIMIT DUE NOT LIMITS IN SRM; PART WILL BE REPARAIBLE BY REPLACEMENT IAW SRM 51-10-02-0G-0; [02] REMOVED ANGLE ACB AT BS 727D+5 LBL5 WL151 IAW SRM 51-40-02-0G-0; [03] VERIFIED CORRECTIVE ACTION STEPS 1 AND 2.; [04] FABRICATED AND DRILLED NEW ANGLE FROM EXTRUSION BAC1493-672#7075-T62 LOT#1458580-1 TO BS 727D+5 LBL5 WL151 WL; 151 IAW SRM 51-40-05-0G-0 AND DWG 146A7730 .OK TO PRIME .; [14] INSTALLED NEW ATTACH ANGLE AT ACB BS727D+5 LBL5 WL151 IAW SRM 51-40-02-0G-0 AND DRAWING#146A7730.<BR>TASK COMPLETE; [15] VERIFIED CORRECTIVE ACTION ITEM 14.; [16] CORRECTED REPAIR TYPE (N/A); [17] VERIFIED TASK IS COMPLETE.