What was found
CRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS914 RBL10 WL171. ; / [01] DAMAGE ON SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 914 WITH CRACK L=0.900 FOUND TO BE OUT LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM AND IT WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G PAR 9C.; [02] VERIFIED CORRECTIVE ACTION ITEM 1.; [03] REMOVED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 914 RBL 10 WL 171; P/N 147A7221-32 IAW SRM 51-40-02.; [04] LOCATED AND DRILLED NEW SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 914 RBL 10 WL 171; P/N 147A7221-32 ;LOT#1466021; PO#833561/1 IAW SRM 51-40-05 AND DWG 147A7221 REV:D.; [05] VERIFIED CORRECTIVE ACTIONS 1-4; [06] OK TO INSTALL.; [07] VERIFIED CORRECTIVE ACTIONS 6; [08] INSTALLED NEW SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 914 RBL 10 WL 171 P/N 147A7221-32; LOT # 1466021 PO #833561/1 IAW SRM 51-40-02 AND 147A7221 REV:D.; [09] UPDATED PARTS INFO; [10] VERIFIED CORRECTIVE ACTION 8-9