What was found
CRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS918 RBL10 WL171. ; / [01] DAMAGE ON SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 918 WITH CRACK L=0.900 FOUND TO BE OUT LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM AND IT WILL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G PAR 9C.; [02] REMOVED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 918 RBL 10 WL 171 P/N 147A7221-32 IAW SRM 51-40-02.; [03] LOCATED AND DRILLED NEW SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGOBAY BS 918 RBL 10 WL 171;P/N 147A7221-32;LOT #1466021 PO#833561/1 IAW SRM 51-40-05 AND DWG 147A7221 REV:D.; [04] VERIFIED CORRECTIVE ACTIONS 1-3; [05] OK TO INSTALL.; [06] VERIFIED CORRECTIVE ACTIONS 5; [07] INSTALLED NEW SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS 918 RBL 10 WL 171 ;P/N 147A7221-32 LOT # 1466021 PO#833561/1 IAW SRM 51-40-02 AND DWG 147A7221 REV:D.; [08] UPDATED PARTS INFO; [09] VERIFIED CORRECTIVE ACTION 7-8