What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS947 RBL17 WL177. ; / [01] REMOVED CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE P/N 149A8118-29 AT BS 947; RBL 17; WL 177; AREA 2.5' X 1' X .020' IAW SRM 51-10-02 -0G-0; FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM. IT'LL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.<BR><BR>TOOL USED ID: IS000686 ; S/N: 67171914; [[10] INSTALLED AFT BULKHEAD TO FLOOR SUPPORT ANGLE P/N 149A8118-29 AT BS 947; RBL 21 FROM LBL 10; WL 177 IAW SRM 51-40-02-0G-0 AND DWG149A8117 ID:004; REV:C; [11] VERIFIED INSTALLATION OF AFT BULKHEAD-TO-FLOOR-SUPPORT ANGLE; BS 947; RBL 17; WL 177 PER SRM 51-40-02 AND DWG 149A8117; [12] VERIFIED ALL WORK STEPS COMPLETE THIS TASK