What was found
CORROSION ON FILLER PANEL JUST BELOW TOILET SERVICE DOOR CUT OUT AT B.S. 847+6 - 867; STRINGER 25 LEFT. ; / [01] REMOVED 4 EACH FASTNERS AT FILLER PANEL JUST BELOW TOILET SERVICE DOOR CUT OUT AT B.S. 847+6-867; STRINGER 25 LEFT PER SRM#51-40-02-0G-0; [02] REMOVED CORROSION BY BLEND OUT AREA L=3.3' W=2.0' PER SRM#51-10-02-0G-0 STEPS 15.A.(6)(A); [03] UPON FURTHER INVESTIGATION; NO ALLOWABLE LIMITS FOUND IN SRM; PART WILL BE REMOVED AND REPLACED.; [04] REMOVED FILLER PANEL JUST BELOW TOILET SERVICE DOOR CUT OUT AT B.S. 847+6-867; STRINGER 25LH PER REF SRM 51-40-02-0G <BR><BR>FABRICATED NEW FILLER FROM MATERIAL .100'' 2024T3 CLAD LOT NBR 1443470-1 PER REF DWG NBR 146A7401 AND SRM 51-40-05; [05] VERIFIED CORRECTIVE ACTION 4.; [06] APPLIED CHEMICAL CONVERSION COATING AND PRIME AT NEW FILLER PANEL PER SRM 51-20-01; [07] VERIFIED CORRECTIVE ACTION 6; OK TO INSTALL GIVEN.; [08] INSTALLED FILLER PANEL BELOW TOILET SERVICE DOOR CUT OUT AT BS 847+6 - 867 STRINGER 25LH PER REF SRM 51-40-02 AND DWG NBR 146A7401; [09] VERIFIED CORRECTIVE ACTION 8.; [10] INSPECTION COMPLETE