What was found
CRACK ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 0.07 CENTER SECTION ; 2021-462040 / [01] REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 0.07 CENTER SECTION IAW DWG 273A9112 REV-AND SRM B737 51-10-02 ITEM 9; [02] CORRECTED STEP 1. REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 0.07 CENTER SECTION IAW DWG 273A9112 REV-AND SRM B737 51-10-02 ITEM 9 SEE INDIVIDUAL SINGNOFFS BELLOW; [03] REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 0.07 CENTER SECTION IAW DWG 273A9112 REV-AND SRM B737 51-10-02 ITEM 9 SEE INDIVIDUAL SINGNOFFS BELLOW RII.