What was found
CRACK ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 24.5 CENTER SECTION ; 2021-462041 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 22-JAN-22; TEMPERATURE CONTROLLER: P/N: 38615K71; S/N: AE-40585; DUE DATE: 07-JUL-22.; [02] REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 24.5 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING # 111A6000 REV. A; [03] UPDATED CORRECTIVE ACTION.<BR>REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 24.5 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING # 111A6000 REV. A. SEE INDIVIDUAL SIGNOFFS BELOW.; [04] REPLACED ANGLE FLOOR STRUCTURE BETWEEN BS 685 TO BS 706 AT LEVEL RBBL 24.5 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING # 111A6000 REV. A. SEE INDIVIDUAL SIGNOFFS BELOW.<BR>RII