What was found
CORROSION ON FWD CARGO L/H FLOOR TO SIDEWALL SUPPORT STRUCTURE AT WL 153 LBL 25 STA 500C+10; LBL 25 STA 500C+14. ; / [01] REMOVED CORROSION AT FCB FLOOR TO SIDEWALL SUPPORT IAW SRM 51-10-02-0G-0; MEASURES L=1.2'' X W=1.0'' X D=0.010 TOOL USED DIGITAL CALIPER ID:ATS2501 S/N:A19335647; MICROMETER ID:ATS1672 S/N:65092939; AND EVALUATED BLENDED AREA AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PART 4A;; [02] REMOVED FCB FLOOR TO SIDEWALL SUPPORT BS400-500D LBL25 WL153 IAW SRM 51-40-02-0G-0; [03] VERIFIED CORRECTIVE ACTION ITEM 1.; [04] VERIFIED ACCOMPLISHMENT OF STEPS 1 & 2.; [05] INSTALLATION OF FLOOR TO SIDEWALL SUPPORT WILL BE PERFORMED ON MOC 5330-E-16461-NG; [06] VERIFIED INSTALLATION OF FLOOR TO SIDEWALL SUPPORT WILL BE PERFORMED ON MOC 5330-E-16461-NG.