What was found
PANEL 661BB HAS MULTIPLE PULLED THROUGH CRACKED FASTENER HOLES ON AFT EDGE ; / [01] IDENTIFIED PANEL 661CB IAW SRM 57-51-01-0I-1 FIGURE 3 ITEM [9] AND TABLE 3 ITEM [9]. DAMAGE IS BEYOND ALLOWABLE LIMITS IAW SRM 57-51-01-1A-1 PARA 4.B.(2) AND WILL BE REPAIRED IAW SRM 51-70-05-2R-9 PER SRM 57-51-01-2R-1 PARA 2.E. REMOVED FULL DEPTH EDGEBAND PLY DAMAGE FROM ALL THE FASTENER HOLES ON THE AFT EDGE; MAX AREA OF REMOVED DAMAGE IS 0.5' ALSO CLEANED REPAIR AREA. WORK ACCOMPLISHED IAW SRM 51-70-05-2R-9 PARA 4.A-C.; [02] CORRECTION TO ITEM 1: CORRECT PANEL IS 661BB NOT 661CB.VALIDATED APPLICABILITY OF SRM 51-70-05-2R-9.;