What was found
CORROSION ON ANGLE P/N 146A8125-53 ATTACHED TO INTERCOSTAL BS 767+5 WL 153 ; / [01] REMOVED DAMAGE ON ANGLE ATTACHED TO INTERCOSTAL AT BS 767 +5 WL 153; RBL 20 AREA .9' X 2' X .010' IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM ; IT'LL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.; [02] VERIFIED REMOVED DAMAGE ON ANGLE ATTACHED TO INTERCOSTAL AT BS 767 +5 WL 153; RBL 20 AREA .9' X 2' X .010' IAW SRM 51-10-02-0G-0. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE FOUND IN SRM ; IT'LL BE REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 STEP 9.C.; [03] RECEIVED NEW ANGLE ITEM:146A8125-53 LOT:1463430-1. <BR>LOCATED AND DRILLED NEW ANGLE IAW SRM 51-40-05-0G-0 AND DRAWING:146A8123.<BR>OK TO INSTALL; [04] VERIFIED LOCATED AND DRILLED NEW ANGLE IAW SRM 51-40-05-0G-0 AND DRAWING:146A8123. <BR>VERIFIED OK TO INSTALL.; [05] INSTALLED NEW ANGLE ATTACHED TO INTERCOSTAL AFT CARGO BAY AT BS 767 TO BS 787 RBL 20 WL 153 IAW SRM 51-40-02-0G-0 DWG 146A8123; [06] VERIFIED INSTALLATION OF NEW ANGLE ATTACHED TO INTERCOSTAL AFT CARGO BAY AT BS 767 TO BS 787 RBL 20 WL 153 IAW SRM 51-40-02-0G-0 DWG 146A8123; [07] CORRECTED ON PART REQUIREMENT; [08] CORRECTED ON PART REQUIREMENT; [09] VERIFIED JOB IS COMPLETE