CABIN FLOOR INTERCOSTAL AT ABOUT BL-0 BETWEEN STA 380-400 UPPER SURFACE CRACKED ; / [01] REMOVED UPPER ANGLE AT CABIN FLOOR INTERCOSTAL ABOUT BL-0 BETWEEN STATION 380 & 400 AS PER SRM 51-40-02-G-0.; [02] LOCATED AND DRILLED NEW ANGLE AS PER SRM 51-40-05-0G-0.; [03] OK TO INSTALL NEW ANGLE; [04] INSTALLED NEW ANGLE AT CABIN FLOOR INTERCOSTAL ABOUT BL-0 BETWEEN STATION 380 & 400 AS PER SRM 51-40-02-0G-0 & DWG 143A5400.; [05] VERIFIED STEP 4; [06] C/W