As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PANEL 145AL GROUND WIRE SCREW EDGES (DOOR SIDE) SHOW SURFACE CORROSION. REMOVED PANEL 145AL IAW SRM 51-40-02-0G-0. REMOVED CORROSION AT PANEL 145AL GROUND WIRE SCREW EDGES IAW SRM 51-10-02-0G-0. PERFORMED UT THICKNESS ON REWORKED AREA IAW NDTM PART 4 51-00-00 PROCEDURE 3 MINIMUM FOUND: 0.024' FOUND OUT OF LIMIT IAW SRM 52-40-01-1A-4 FIGURE 103 DETAIL D. INSTALLED NEW DOOR PANEL (145AL) IAW SRM 51-40-02-0G-0.