What was found
MULTIPLE CRACKS EMANATING FROM FASTENER HOLE OPPOSITE FITTING LATCH (2 CRACKS) AND ALSO FROM THE FWD ADJOINING FASTENER HOLE (3 CRACKS). ; / [01] INSTALLED EWIS PROTECTION AS PER AMM 20-60-07-913-801; [02] APLIED STRIPPING FOR REMOVE PAINT REMOVED PAINT AND STRIPPING AND CLEAN AREA AS PER AMM 51-21-11-150-810; [35] DAMAGE REPAIRED PER EA 21-153-02897 (737-700 SRM 53-10-01-2R-6);REPETITIVE INSPECTION PROGRAM DEFINED IN EA 21-153-02897-INSP; [36] VERIFIED 33;34 & 35