What was found
LIGHT CORROSION AT AFT PRESSURE DOME FWD SIDE BS 1016, CIRCUMFERENTIAL SKIN SPLICE BETWEEN STRINGERS 26L TO 26R. REMOVED SKIN ATTACH RIVETS AT AFT PRESSURE DOME IAW SRM 53-80-08-1A-1 CORROSION FOUND OUT OF LIMITS IAW SRM 53-80-08-1A-1. REMOVED SPLICE ANGLE IAW SRM 51-40-02-0G-0. FABRICATED SPLICE ANGLE & HEAT TREATMENT IAW DWG 148A2216, & SRM 51-40-05-G-0. TREATED AND PRIMED NEW SPLICE ANGLE IAW AMM 51-21-52-370-804 & SRM 51-20-01-0G-0. INSTALLED RIVETS IAW DWG 147A0070. REINSTALLED BOLTS IAW SRM 51-40-04-0G-0 TABLE B FIG (1). INSTALLED STRINGER TIE IAW SRM 51-40-02-0G-0. SEALED FASTENERS IAW SOPM 20-50-19.