What was found
CRACKED FLOOR SUPPORT BS 312-328 RBL 30 WL 208 ; / [01] REMOVED CRACKED SUPPORT AND INSTALLED NEW SUPPORT IAW DWG 141A5400 SH 26 AND SRM 51-40-02; [02] VERIFIED CORRECTIVE ACTION 1.; [03] VERIFIED ALL STEPS COMPLETE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED FLOOR SUPPORT BS 312-328 RBL 30 WL 208 ; / [01] REMOVED CRACKED SUPPORT AND INSTALLED NEW SUPPORT IAW DWG 141A5400 SH 26 AND SRM 51-40-02; [02] VERIFIED CORRECTIVE ACTION 1.; [03] VERIFIED ALL STEPS COMPLETE.