What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT BS500A+7; BS500C+2; BS500C+6.5 RBL24 WL156. ; / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 465 REMOVED 0.010' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-2 USING ATS TOOL ID ATS1225 S/N UNKNOWN; [02] CORRECTION TO CORRECTIVE ACTION STEP 1. EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500C+2' REMOVED 0.010' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-2 USING ATS TOOL ID ATS1225 S/N UNKNOWN; [03] VERIFIED ACTION 1;2; [04] FABRICATED NEW R/H FLOOR TO SIDEWALL SUPPORT BS 500A TO 500D RBL24 WL 156 FROM EXTRUSION BAC1496-444#7075T62 CLAD LOT# 1467644-1; AND LOCATED AND DRILLED PER SRM 51-40-02-0G-0; DWG 143A7500; AND DWG 143A7501; [05] APPLIED CHEMICAL CONVERSION COATING; PRIMER AND INSTALLED NUTPLATES PER SOPM 20-43-03; AMM 51-21-72-370-804; AND DWG 143A7501; [06] VERIFIED CORRECTIVE 4.; [07] VERIFIED ALL STEPS COMPLETE.; [08] CORRECTION TO CORRECTIVE ACTION STEPS 1 AND 2. IT SHOULD BE SRM 53-00-53-1A-2.