What was found
CORROSION ON AFT BULKHEAD TO SIDEWALL SUPPORT AT FWD CARGO BAY BS 500D RBL25 157. ; / [01] EVALUATED CORROSION; REMAINING THICKNESS LESS THAN 0.056' IN A AREA OF 1X1 FOUND TO BE OUT OF LIMITS PER SRM 53-30-08-1A-1 USING ATS TOOL ID ATS1225 S/N UNKNOWN.; [02] VERIFIED ACTION 1; [03] LOCATED AND DRILLED NEW FWD CARGO BAY R/H AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS 500D RBL25;WL157 PER SRM 51-40-05-0G-0; DWG 143A7902; AND 143A9481; [04] ADDED PART USE; [05] VERIFIED CORRECTIVE ACTION 3.; [06] VERIFIED ALL STEPS COMPLETE.