What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 RBL20 WL180. ; / [01] CORROSION ON SUPPORT ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.; [02] VERIFIED CORRECTIVE ACTION 1.; [03] REMOVED SUPPORT PER SRM 51-40-02; [04] LOCATED AND DRILLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE BS 947 RBL20 WL180 PER SRM 51-40-05-0G-0 AND DWG 149A8117; [05] VERIFIED CORRECTIVE ACTION STEP 4.; [06] OK TO INSTALL SUPPORT ANGLE; [07] VERIFIED STEP 6; OK TO INSTALL; [08] OK TO INSTALL CENTER AFT CARGO BULKHEAD SUPPORT ANGLE BS907; [09] INSTALLED CENTER AFT CARGO BULKHEAD SUPPORT ANGLE BS947 PER SRM 51-40-02-0G-0 AND DWG 149A8117; [10] VERIFIED STEP 9; [11] VERIFIED INSTALLATION OF THE AFT BULKHEAD FLOOR SUPPORT AT BS947 PER SRM 51-40-02-0G-0 AND DWG 149A8117; [12] WORKSCOPE COMPLETE ON REPLACEMENT OF THE BS947 AFT CARGO BAY AFT BULKHEAD TO FLOOR SUPPORT.