What was found
CRACK SERVICE DOOR CUT OUT STUB FRAME LOCATED AT LEVEL BS294.5 AND STR17R AT FWD GALLEY AREA ; 2021-460762 / [01] EVALUATED STUB FRAME FOR CRACK LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA ALLOWABLE DAMAGE NOT FOUND ON SRM B737-700 AND MUST BE REPAIR MESUARE OF CRACK IS L= 1.990? TOOL USED CALIPER P/N: DIGITAL 150 S/N:AE-412610 DUE DATE: 21-MAY-22;REPAIRED STUB FRAME FOR CRACK LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 53-10-15-2R-7 REPAIR 7; AND DWG: 141A8430 REV. B ; DWG 141A8370 REV. D. SEE INDIVIDUAL STEP SIGN OFFS BELOW; [10] CERTIFIED STEP 9 RII.