What was found
CORROSION ON SUPPORT INTERCOSTAL AT B.S. 259+3 - 259+8; L.B.L 3 - R.B.L. 3; W.L.207.54. REMOVED CORROSION ON SUPPORT INTERCOSTAL. FOUND TO BE OUT LIMITS ALL IAW SRM 51-10-02-0G-0, AND SRM 53-10-51-1A-1, ALLOWABLE DAMAGE 1 FIG 104 GROUP 2 PAR 4.B (2) (A) DETAIL C & E. REMOVED SUPPORT INTERCOSTAL AND LOCATED, DRILLED AND INSTALLED THE NEW SUPPORT INTERCOSTAL IAW DWG 141A5210, SRM 51-10-05-0G-0 AND SRM 51-40-02-0G-0.