As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION LOCATED AT APPROX. 6 O'CLOCK POS. STA. 1016 JUST FWD OF DRAINS. 1] CLEANED AREA IAW SRM 51-10-02-0G-0. FOUND UPPER SPLICE ANGLE WITH EXFOLIATING CORROSION OUT OF LIMITS. REMOVED FWD SPLICE ANGLE IAW SRM 51-40-02, FABRICATED SPLICE ANGLE IAW DWG 148A2216. LOCATED AND DRILLED NEW SPLICE ANGLE IAW SRM 51-40-05-0G-0.