What was found
FWD CARGO BAY; AFT CORNER SCUFF PLATE IS CRACKED. WELDED CRACK ON SCUFF PLATE IAW SRM 53-30-15-2R-1 PARA 4.B. (2) ACCOMPLISHED DYE PEN INSPECTION ON WELDED AREA IAW SOPM 20-20-02. ACCOMPLISHED DYE PEN INSPECTION ON WELDED AREA IAW SOPM 20-20-02. WELDED CRACKED AREA AS INDICATED BY NDI ON FCB AFT CORNER SCUFF PLATE IAW SRM 53-30-15-2R-1 PARA 4.B. (2) AND (4). PT INSPECTED SCUFF PLATE IAW SOPM 20-20-02. NO CRACKS NOTED. SANDED WELD REPAIR AREA SMOOTH IAW SRM 53-30-15-2R-1 PARA 4.B.(5). APPLIED CHEMICAL CONVERSION TO BARE ALUMINUM SURFACES AND APPLIED 2 COATS OF PRIMER IAW SRM 53-30-15-2R-1 STEPS 4.B(6) AND (7); [12].