What was found
AFT CARGO BAY; AFT CORNER SCUFF PLATE IS CRACKED. WELDED CRACK IAW SRM 53-60-15-2R-1 PARA 4.B. (2) AND (4). FLOURESCENT DYE PENETRANT INSPECTED REPAIRED AREA IAW SOPM 20-20-02 METHOD C. CRACK NOTED. WELDED CRACK AS INDICATED BY NDI IAW SRM 53-60-15-2R-1 PARA 4.B. (2) AND (4). INSPECTED SCUFF PLATE IAW SOPM 20-20-02. NO CRACKS NOTED. SANDED WELD REPAIR AREA SMOOTH IAW SRM 53-60-15-2R-1 PARA 4.B.(5). APPLIED CHEMICAL CONVERSION TO BARE ALUMINUM SURFACES AND APPLIED 2 COATS OF PRIMER IAW SRM 53-30-15-2R-1 STEPS 4.B(6) AND (7); [11].