What was found
CORROSION FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 500A +6; +10; +17; BS 500B +2; +6; +10; +14; BS 500C +2 RBL 26 WL 156 ; / [01] EVALUATED CORROSION AT ALL LOCATION; FOUND DEEPEST LOCATION AT BS 500C+2 RBL 26 WL 156. FOUND 0.015 REMOVED FROM ORIG 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 1225 S/N UNKNOWN; [02] VERIFIED OUT OF LIMITS; [03] FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS 500A-500D; LOCATED AND DRILLED IAW SRM 51-40-05-0G-0; DWG 143A7500; MATERIAL; BAC1496-444 #7075T62; LOT#5098100-1; APPLIED CHEMICAL CONVERSION COATING; IAW SRM 51-20-01-0G-0; AND OK TO PRIME; [04] VERIFIED FABRICATED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS 500A-500D; LOCATED AND DRILLED IAW SRM 51-40-05-0G-0; DWG 143A7500; MATERIAL; BAC1496-444 #7075T62; LOT#5098100-1; APPLIED CHEMICAL CONVERSION COATING; IAW SRM 51-20-01-0G-0; AND OK TO PRIME; [05] PRIMED NEW FCB RH FLOOR TO SIDEWALL SUPPORT; BS 500A-500D; IAW SRM 51-20-01-0G-0.; [06] PRIMED NEW RH FLOOR TO SIDEWALL SUPPORT; BS 395-420; IAW SRM 51-20-01-0G-0