What was found
CRACKED STRINGER AT AREA AFT OF FCB BS540 S-26L WL153. MARKED ; / [01] EVALUATED CRACK MEASUREMENTS ON FCB STR 26L BS 536 ; STRINGER DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1 FIG 103; [21] REPAIRED STRINGER 26L; BETWEEN STA 500D-520; WL 153 I.A.W SRM 53-00-03-2R-1 REPAIR 1.; [22] CORRECTION FOR ITEM 21- REPAIRED STRINGER 26L; BETWEEN STA 500D-540; WL 153 I.A.W SRM 53-00-03-2R-1 REPAIR 1.; [23] VERIFIED INSTALLATION OF REPAIR PARTS FOR S-26L; BS 500D-540; WL 153; PER SRM 53-00-03-2R-1; REPAIR 1; [24] VERIFIED ALL WORK COMPLETE THIS TASK