As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PANEL 191D HAS MULTIPLE CRACKED FASTENER HOLES ALONG R/H AND L/H EDGEBANDS. DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-30-70-1A-1 PAR 4B(1B). COMPLETED DAMAGE REMOVAL ON INNER SURFACE EDGEBAND IAW SRM 51-70-05-2R-6 PAR 4A-D. FABRICATED REPAIR PLIES IAW SRM 51-70-05-2R-6 PAR 4E-F. JOB COMPLETE PER SRM 51-70-05-2R-6.