What was found
CORROSION ON CARGO TRACK AT BS 772, LBL 3, WL 157. FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED BY TRIMMING OUT AN AREA L=3.26' X W= .9' IAW SRM 53-00-53-2R-2, REPAIR 2. HFEC INSPECTED TRIMMED EDGE OF DAMAGE CUTOUT IAW NDT PART 6 51-00-00 PROCEDURE 23. NO CRACKS FOUND. FABRICATED, LOCATED, AND DRILLED NEW SPLICE AND APPLIED CHEMICAL CONVERSION COATING IAW SRM 53-00-53-2R-2, PAR 4, FIG 203, DETAIL F. APPLIED PRIMER ON SPLICE REPAIR IAW SRM 53-00-53-2R-2, PAR 4. FIG 203, DETAIL F. INSTALLED SPLICE REPAIR IAW SRM 53-00-53-2R-2, PAR 4, STEP Q, FIG 203, DETAIL F.