What was found
CABIN FLOOR PANEL 232RF, AFT 2EA CORNERS CRUSHED & DELAMINATED. TAP TESTED DAMAGED AREA, DELAMINATION AND DAMAGED CORE IS REPAIRABLE IAW SRM 53-00-50-2R-0, TABLE 201. CLEANED AND PREPPED DAMAGED AREAS AND POTTED DAMAGED CORE IAW SRM 53-00-50-2R-1, PAR 3 STEPS A;C;D;E;F;G;H;I; AND J. BONDED REPAIR PLIES IAW SRM 53-00-50-2R-1, PAR 3, STEPS K;L; AND M, AND IAW SRM 53-00-50-2R-0, REPAIR GENERAL. REPAIRED CABIN FLOOR PANEL 232RF AFT 2 EA CORNERS IAW SRM 53-00-50-2R-1 PAR 3 AND SRM 53-00-50-2R-0, REPAIR GENERAL.