What was found
CRACKED LOWER R/H COMPOSITE BULKHEAD AT BS663 RBL39 WL161. MARKED ; / [01] IDENTIFIED MATERIAL OF VAPOR BARRIER WEB IAW SRM 57-10-10-0I-2 FIGURE 1 AND 2; ITEM# 4; TABLE 2<BR><BR>DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PARA 4.D(1)<BR><BR>REPAIR TO BE ACCOMPLISHED IAW SRM 51-70-04-2R-10 PER SRM 57-10-10-2R-2 PARA 1.C<BR><BR>VISUALLY EXAMINED 4 AREAS OF DAMAGE; TAP TESTED - DISBOND NOTED; AREA #1; REMOVED .5' X .5' OF DAMAGE AT IB EDGE AND 10' FROM TOP EDGE; AREA #2; REMOVED 1' X 5.5' OF DAMAGE AT 22' FROM IB EDGE AND TOP EDGE TO 4' DOWN; AREA #3; REMOVED 1' X 21' OF DAMAGE 34' FROM IB EDGE AND TOP EDGE TO LWR EDGE; AREA #4; REMOVED 1' X 1.5' OF DAMAGE 49' FROM IB EDGE AND 1.5' FROM LWR EDGE