What was found
CORROSION ON ACB RH FLOOR-TO-SIDEWALL SUPPORT, BS 727E+8'; 727E+12; 727E+15 AND 727E+18'; RBL 21. REMOVED CORROSION AND FOUND TO BE OUT LIMITS AT BS.727E+8';L=1.800' W=0.600' D=0.011' ORIGINAL THICKNESS 0.040'REMAINING THICKNESS 0.029 IAW SRM 53-00-53-1A-2 FIG 103 DETAIL C, LOCATED AND DRILLED A NEW SUPPORT IAW SRM 53-00-53-2R-6. APPLIED PRIMER IAW AMM 51-21-72-370-804. INSTALLED NEW SIDEWALL SUPPORT IAW 51-40-02-0G AND DWG 146A7500.