What was found
CORROSION OF FWD CARGO LT FLOOR-TO-SIDEWALL SUPPORT, BS 440+2'; 440+10' AND 440+14'; BS 500+14'; LBL 25. REMOVED CORROSION, OUT OF LIMITS IAW SRM 53-00-53-1A-2, ALLOWABLE DAMAGE 2, STEP 4.2A. LOCATED AND DRILLED A NEW SIDE WALL SUPPORT ANGLE AND SPLICE ANGLE IAW SRM 51-40-05-0G-0 AND SRM 53-00-53-2R-5 REPAIR-5. APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW AMM 51-21-72-370-804, AND AMM 51-21-41-370-802. INSTALLED THE FLOOR TO SIDEWALL IAW CARD TTG8Q004ETN1.