What was found
CORROSION ON FCB FWD SHIELD; UNDER FASTENER HOLE; BS 420+2'; RBL 24 (MARKED) ; / [01] DAMANGE FOUND ON FCB FWD SHIELD BS 420-440 RBL 24 WL156 P/N 143A8126-22 FOUND TO BE OUT OF LIMIT IAW SRM PART WILL BE REPAIRED BY REMPLACEMENT IAW SRM 51-10-02-0G-0 PAR. 9C; [02] VERIFIED ITEM 1 CORRECTIVE ACTIONS.; [03] RECEIVED FCB FWD SHIELD P/N 143A8126U21; PO# 846329/1.<BR><BR>LOCATED AND DRILLED NEW FCB FWD SHIEL AT BS 420 TO BS 440 RBL 24; WL 156 IAW SRM 51-40-05 AND DWG 143A8126; ID: 011 ; REV: A.; [04] INSTALL SHIELD WILL BE ACCOMPLISHED ON C.C. TTG8Q004ETN1; [05] VERIFIED LOCATED AND DRILLED NEW FCB FWD SHIEL AT BS 420 TO BS 440 RBL 24; WL 156 IAW SRM 51-40-05 AND DWG 143A8126; ID: 011 ; REV: A.