What was found
CABIN FLOOR PANEL 242BF LOWER SURFACE; CORNER CRUSHED /DELAMINATED. DOT 234/06 ; / [01] EVALUATED FLOOR PANEL 242BF AND FOUND LOWER SURFACE CORNER CRUSHED. DAMAGE IS WITHIN REPAIRABLE LIMITS IAW SRM 53-00-50-2R-4 REV. 74<BR><BR>VERIFIED REPAIR MATERIALS AS BMS9-3 TY H3 (A10273); BMS8-201 (A102320); AND BMS5-28 TY 19 (A101798) IAW SRM 53-00-50-2R-4 REV. 74 TABLE 201<BR><BR>REMOVED DAMAGE; PREPPED; AND POTTED CORE IAW SRM 53-00-50-2R-4 REV. 74 PARA. 3. (A.-J.) AND SRM 53-00-50-2R-0 REV. 74 PARA. 5. <BR><BR>*REQUESTING OKAY TO BOND*; [02] STEP 1 OK. OK TO BOND; [03] APPLIED AND BONDED REPAIR PLIES TO AREA AND CURED @ 150F FOR 3HRS; THERMOMETER #30347 DUE 4/29/22; BOND IS SATISFACTORY/NO DEFECTS IAW SRM 53-00-50-2R