What was found
CRACK AROUND THE FASTENER AT NO.8 SLAT LOWER SURFACE OF THE L/E SLAT NOSE SKIN AT ACTUATOR RIBS. EDDY CURRENT INSPECTED AREA IAW NDT MANUAL PART 6; 51-00-00 PROCEDURE 23. EXTENT OF CRACK NOTED APPROXIMATELY .100 INCHES IN LENGTH. INSTALLED REPAIR PARTS IAW SRM 57-42-01-2R-8; ALTERNATIVE 1; STEP L. COMPLETED STEPS M;O;P;Q IAW SRM 57-42-01-2R-8; ALTERNATIVE 1.; [16] COMPLETED STEP R; BOLT RETAINER INSTALLED. IAW SRM 57-42-01-2R-8; ALTERNATIVE 1; STEP .; [17] ACCOMPLISHED SLAT 8 REP IAW SRM 57-42-01-2R-8; ALTERNATIVE 1.