What was found
PANEL 561BB HAS NUMEROUS CRACKED PULLED THROUGH SEAL FASTENER HOLES ON T/E. EXCEED ALLOWABLE LIMITS IAW SRM 57-51-01-1A-1 PARA 4 B. REPAIR TO BE PERFORMED IAW SRM 51-70-05-2R-9, SRM 57-51-01-2R-1 PARA 4 D TABLE 202. PERFORMED DAMAGE REMOVAL & SURFACE PREPARATION STEPS AS GIVEN IN SRM 51-70-05-2R-9 PARA 4 STEPS A-C. PREPARED THE REPAIR SURFACE IAW SRM 51-70-05-2R-9 PARA 4 STEPS H- J . FABRICATED THE REPAIR PLIES, LAID UP THE REPAIR, VACUUM BAGGED, LEAK CHECKED, SET TO CURE IAW SRM 51-70-05-2R-6 PARA 4 STEPS K & L. REPAIRED IAW SRM 51-70-05-2R-6.