What was found
RT OVERWING EMERGENCY EXIT CUTOUT STRUCTURE IS CORRODED ON THE LWR SILL, BS 635-619 RBL 71. SIX RIVETS REMOVED FOR ACCESS IAW SRM 51-40-02-0G-0. CORROSION REMOVED EMERGENCY EXIT CUTOUT STRUCTURE LOWER SILL WEB IAW SRM 51-40-15-1A-1, DAMAGE ALLOWED 1 PARAGRAPH 2.A. WITHIN LIMITS IAW SRM 53-40-15-1A-1. BS 625 OUT OF LIMITS DUE TO PROXIMITY TO DRAIN HOLE PER SRM 53-40-15-1A-1 FIG 102. BLEND MEASURES .9' X .4' X .001'. BLEND OUT AT BS 625 REPAIR ACCOMPLISHED ON 21-153-03550-WIP1. APPLIED CHEMICAL CONVERSION COATING & PRIMER IAW SRM 51-20-01 AND SOPM 20-41-02 AND INSTALLED RIVETS IAW SRM 51-40-02 AND DWG 144A8201.