What was found
FORWARD CARGO FLOOR STRUCTURE R/H TRANSITION ANGLE STA. 500A-500D HAS NUMEROUS AREAS OF SURFACE CORROSION AROUND FASTENER HOLES. (MARKED) ; / [01] FABRICATED R/H TRANSITION ANGLE FROM STA 500A-500D I.A.W SRM 51-40-05. INSTALLATION OF NEW PART TO BE ACCOMPLISHED ON MT 5330-E-16461.; [02] C/W INSPECTION FABRICATED R/H TRANSITION ANGLE FROM STA 500A-500D I.A.W SRM 51-40-05. INSTALLATION OF NEW PART TO BE ACCOMPLISHED ON MT 5330-E-16461.