What was found
FORWARD CARGO FLOOR STRUCTURE AFT BULKHEAD ANGLE AT STA 500D LBL24-RBL24 HAS NUMEROUS AREAS OF SURFACE CORROSION. (MARKED) ; / [01] REMOVED ANGLE IN ORDER TO BLENDED CORROSION PER SRM 51-10-02 ; FOUND TO BE OUT OF LIMITS .; [02] MEASUREMENT REQUIREMENT .; [03] BLENDED AREA IAW SRM 51-10-02; AREA IS OUT OF LIMITS IAW SRM 53-30-08-1A-1.; [04] VERIFIED BLENDED AREA IAW SRM 51-10-02; AREA IS OUT OF LIMITS IAW SRM 53-30-08-1A-1.; [05] NEW ANGLE INSTALLED ON TTG8Q004FUDH; [06] NEW ANGLE INSTALLED ON TTG8Q004FUDH C/W INSPECTION