What was found
CRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 - L.B.L. 24.5; W.L. 208.1. ; / [01] FLOOR SUPPORT REMOVED BTW BS540; BL.0; LBL 24.5; WL. 208.1 IAW SRM 51-40-02-0G-0; PART NO HAS ALLOWABLE DAMAGE IN SRM. MUST BE REPAIRED BY REPLACEMENT<BR>IAW. SRM 51-10-02-0G-0 PARAGRAPH. 9.C.; [02] RECEIVED FLOOR SUPPORT WITH P/N 143A5240-35; LOT.1472074; LOCATED AND DRILLED IAW SRM 51-40-05-0G-0 DWG# 143A0060. OK TO INSTALL.; [03] VERIFIED CORRECTIVE ACTIONS #1 AND #2; [04] INSTALLED FLOOR SUPPORT LOCATED BTW BS.540; B.L.0 - LBL 24.5; WL 208.1 IAW SRM 51-40-02-0G-0 AND DWG# 143A0060. ALL MAINTENANCE ACTION ARE COMPLETE.