CRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 - R.B.L. 24.5; W.L. 208.1. ; / [01] FLOOR SUPPORT REMOVED BTW BS540; BL.0; RBL 24.5; WL. 208.1 IAW SRM 51-40-02-0G-0; PART NO HAS ALLOWABLE DAMAGE IN SRM. MUST BE REPAIRED BY REPLACEMENT <BR>IAW. SRM 51-10-02-0G-0 PARAGRAPH. 9.C.; [02] RECEIVED FLOOR SUPPORT WITH P/N 143A5240-36; LOT.1474227-1; LOCATED AND DRILLED IAW SRM 51-40-05-0G-0 DWG# 143A0060. OK TO INSTALL.; [03] INSTALLED FLOOR SUPPORT LOCATED BTW BS.540; B.L.0 - RBL 24.5; WL 208.1 IAW SRM 51-40-02-0G-0 AND DWG# 143A0060. ALL MAINTENANCE ACTION ARE COMPLETE.