What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 419. REMOVED CORROSION, L=.4 X W=.5 X D=0.008 ORIGINAL THICKNESS 0.040 MAT REMAINING 0.032 FOUND TO BE OUT LIMITS PER SRM 53-00-53-1A-2 STEP 4.A.(2)(A) DETAIL D. FABRICATED NEW FLOOR TO SIDEWALL. LOCATED & DRILLED IAW SRM 51-40-05; SRM 53-30-53-01-02 TABLE 2, DWG 143A7501. APPLIED CHEMICAL CONVERSION COAT IAW. 51-20-01. APPLIED PRIMER TO SIDEWALL SUPPORT AT RBL 24 BS 400 TO BS 420 IAW SOPM 20-40-01. VERIFIED APPLICATION OF PRIMER IAW SOPM 20-41-02; FCB FLOOR TO SIDEWALL SUPPORT RBL 24 BS 419 WILL BE INSTALLED ON CUSTOMER CARD # TTG8Q004FMEJ.