What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727E-727E+2; BS 727E+5-727E+6; BS 727E+12; BS 727E+14-727E+15; BS 747+2-767. REMOVED CORROSION, FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2 PARA 4A FIG 103 DETAIL D. MANUFACTURED IAW DWG 146A-3773, DRILLED IAW SRM 51-40-02, INSTALL SIDEWALL SUPPORT WILL BE ACCOMPLISHED ON C.C.TTG8Q004F1L2.