What was found
A-061 DOT 003 AFT CARGO PIT WASTE TANK ENCLOSURE VERTICAL BEAM AT STA 847+18' LBL 10 LOWER ATTACH ANGLE CRACKED ; / [01] REMOVED CRACKED CLIP IAW SRM 51-40-02.; [02] LOCATED/DRILLED NEW CLIP; 149A8109U114; IAW SRM 51-40-05. A TAG # A94253.; [03] OK TO INSTALL CLIP 149A8109U114.; [04] VERIFIED STEPS 1-3. OK TO INSTALL CLIP; [05] INSTALLED NEW CLIP; 149A8109U114; IAW BOEING DWG# 149A8109 REV. B & SRM 51-40-02.; [06] APPLIED CIC IAW AMM 51-21-91.; [07] REMOVED AND REPLACED LOWER CLIP AT VETICAL BEAM; STA 847+18 LBL 10; IAW SRM 51-40-02 & DWG # 149A8109 REV. B.; [08] VERIFIED STEPS 5-7<BR>AUDIT C/W