What was found
FWD CARGO FLOOR STRUCTURE; BAFFLE/INTERCOSTAL AT STATION 500H INBOARD SIDE SUPPORT CLIP CRACKED. DOT 234/10 ; / [01] DRILLED AND REMOVED CRACKED R/H STA500H CLIP IAW SRM 51-40-02-0G-0; [02] VERIFIED NEW CLIP STA 500H R/H SIDE AS P/N 143A7502-158 IAW BOEING DWG 143A7505 REV:-; [03] 'A' TAG NUMBER 'A' 573 FOR STEP 2 ABOVE CLIP P/N 143A7502-158; [04] VERIFIED STEP 2 AND 3; [05] LOCATED AND DRILLED NEW R/H STA 500H CLIP IAW SRM 51-40-05-0G-0; [06] INSPECTION CW STEP 5; [07] OK TO INSTALL; [08] INSTALLED NEW R/H STA500H CLIP IAW SRM 51-40-02-0G-0 ALSO BOEING DWG 143A7505 REV:-; [09] CLIP IS INSTALLED AND APPLIED CIC TO AREA IAW AMM 51-21-91-701; [10] RII CW; [11] STEP 8 -9 INSPECTION CW